Is EN 1348 still current?+
No. EN 1348:2007 was withdrawn in February 2017 and superseded by EN 12004-2:2017, Adhesives for ceramic tiles — Test methods, which absorbed it along with EN 1308, EN 1323, EN 1324, EN 1346, EN 12002 and EN 12003. The method itself was carried across rather than dropped, so the work is unchanged; only the reference has moved. A drawing or tender still citing EN 1348 should be read as calling for the tensile adhesion method now published in EN 12004-2.
What does EN 1348 measure?+
The tensile adhesion strength of a cementitious tile adhesive — the force needed to pull a tile perpendicularly off a standard concrete slab, divided by the bonded area, reported in newtons per square millimetre. That is adhesion in the direction that actually pulls a tile off a wall, which is why it is the figure the classification system is built on.
Why are there four results rather than one?+
Because the method is run after four different histories: standard conditions to 28 days, water immersion, heat ageing at 70 °C for 14 days, and 25 freeze-thaw cycles. An adhesive that is strong dry and weak after immersion is the wrong adhesive for a shower whatever its dry figure says, and one that survives water but not freeze-thaw is wrong for an external terrace. The set of four is the result; any one of them alone is a fragment.
How do C1 and C2 relate to this test?+
They are classes in the requirements standard, EN 12004-1:2017, and an adhesive earns one by clearing the stated limits in each of the named conditioning regimes. The strength figures come from this method, so the class is a summary of a set of EN 1348 results rather than a separate property. Reporting one regime and letting it stand for the class is how a product ends up compliant on paper and not on site.
Why is the load applied at a rate of force rather than displacement?+
Because the method specifies it: the force increases at a constant 250 N/s, plus or minus 50, until the bond fails. Running the frame in displacement control instead makes the loading history depend on how stiff each assembly happens to be, so nominally identical specimens see different rates and the scatter grows for a reason that has nothing to do with the adhesive.
What machine does the test need?+
A modest one. Capacity is not the constraint — a tile of this size at a few newtons per square millimetre fails in single-digit kilonewtons — so what matters is a truly perpendicular pull, steady force-rate control to failure, and a load cell chosen for that range rather than for the frame. Conditioning capability is as much part of the requirement as the frame, since immersion, heat ageing and freeze-thaw cycling all have to run to schedule.
What is the commonest way this test goes wrong?+
A pull-head bonded out of square, which peels one edge first and gives a low result with a misleading failure surface. After that: bonding adhesive that has not fully cured, so the head releases before the mortar and the test has measured nothing; slabs drifting from the standard specification or varying in porosity between batches, which reads as adhesive variability; and reporting a figure without naming the conditioning regime it came from.
Why does the concrete slab have to be a standard one?+
Because porosity and surface texture govern how much water the substrate draws out of the adhesive while it sets, and that in turn governs the bond. Leaving the slab to whatever the laboratory had makes results incomparable between laboratories and between batches. The slab specification travelled with the method: it was EN 1323 while EN 1348 stood, and EN 12004-2 absorbed both in 2017.